Hypertherm V9 Series Phoenix Rev.11 User Manual
Page 86

86
Phoenix 9.76.0 Installation and Setup Manual 806410
2 – Machine Setup
In the following illustration, the Torch Height Disable output is activated based on the values of the setup parameters.
For these values, the Torch Height Disable output is active
1
2.7 mm (0.5 inches) before and 2.7 mm (0.5 inches) after
each 90 degree corner. This output is also activated as the torch accelerates away from the pierce and through the arc
because the speed is below the Torch Height Disable Speed value. Finally, because the arc intersects at greater than the
20-degree tangent angle, the Torch Height Disable output is activated for 0.5 inches before and after the beginning of
the arc, and is activated for 0.5 inches before and after the end of the arc.
Parameter
Value
Torch Height Disable Speed Percentage value
90%
Distance Before THC Speed value
12.7 mm (0.5 inches)
Distance After THC Speed value
12.7 mm (0.5 inches)
Tangent Angle Value
20 degrees