Phoenix 9.76.0 Installation and Setup Manual 806410

7 – Plasma Setup

MAXPRO200 Diagnostic screen

The MAXPRO200 Diagnostic screen reports the status of several MAXPRO200 conditions and enables you to perform
certain diagnostic functions to aid troubleshooting. To display the screen, choose Setups > Diagnostics, then choose the
MAXPRO200 soft key.

MAXPRO200 Information: Default range of system status settings that displays on the Diagnostic screen to help with

troubleshooting. Use the other soft keys on the screen to start (or stop) certain diagnostic modes or to reset
the system.

Current Setpoint: Amperage set for the MAXPRO200 power supply.

Coolant Flow: Rate at which the coolant is flowing.

State: The currently active state of the MAXPRO200 power supply.

Error: Code and description identifying the system error that has occurred, if any. For a more detailed description of each

error and for possible corrective actions you can take, refer to the Troubleshooting table in the
“Maintenance” section of the

MAXPRO200 Instruction Manual (807700).

Torch ID: Number and description identifying the combination of lead length and torch type installed.

Firmware: Version of the firmware installed on the MAXPRO200 power supply.

Inlet: Initial measured inlet gas pressure.