274

Phoenix 9.76.0 Installation and Setup Manual 806410

15 – Oxyfuel Application

2. Select the gas channel and assign an analog output and maximum pressure for it. The channels are listed in groups.

Each channel in each group should be selected and matched with an analog output. The CNC transfers these
channels and pressures to the Oxyfuel Process screen.

Setting gas pressures from the CNC

You can adjust the pressures on the Oxyfuel Process screen. Each pressure has a ramp-up time. The oxyfuel cut chart
provides the starting set of values.

Oxyfuel torch pressures

Analog outputs to assign

Standard

Cut Oxygen

Preheat Oxygen

Preheat Fuel

Triple bevel torch 2

Cut Oxygen TBT 2

Preheat Oxygen TBT 2

Preheat Fuel TBT 2

Triple bevel torch 3

Cut Oxygen TBT 3

Preheat Oxygen TBT 3

Preheat Fuel TBT 3

Triple bevel preheat torch

Preheat Oxygen TBPT

Preheat Fuel TBPT