Sensor thc axis screen, Station configuration screen – Hypertherm V9 Series Phoenix Rev.11 User Manual
Page 117

Phoenix 9.76.0 Installation and Setup Manual 806410
117
3 – Torch Height Control Axis Setup
Sensor THC Axis screen
Station Configuration screen
For Station 1, choose the Sensor THC as the lifter.
Parameter
Setting
Proportional Gain
50
feedforward Gain
0
Derivative Gain
0
Velocity Gain
150
Integral Gain
0
Voltage Gain
40
Servo Error Tolerance
5.08 mm (0.2 inch)
Stall Force Tolerance
0.51 mm (0.02 inch)
Encoder Counter mm/in
1028.35 counts/mm
(26120 counts/inch)
Encoder Polarity
Positive
DAC Polarity
Negative
Drive Type
Current
Encoder Decode Mode
4X
Slide Length
165.1 mm (6,5 in)
Home
to Hard Stop Current Limited
Current Limit
25%
Home Current Limit
25%
IHS Current Limit
8%
Plasma Tracking Mode
Normal
Average Voltage Over
25 msec