15 – Oxyfuel Application

The following table illustrates the output activation for the three modes. When you run the part, the Creeping message
displays as the status when the I/O that are associated with these parameters activate.

Mode 1

Mode 2

Mode 3

Staged Pierce Output

(number) = (state)

Staged Pierce Output

(number) = (state)

Staged Pierce Output

(number) = (state)

Torch reaches creep
speed

1 = On
2 = Off
3 = Off
4 = Off

1 = On
2 = Off
3 = Off
4 = Off

1 = On
2 = Off
3 = Off
4 = Off

Staged Pierce Time 1
expires

1 = On
2 = On
3 = Off
4 = Off

1 = On
2 = On
3 = Off
4 = Off

1 = Off
2 = On
3 = Off
4 = Off

Staged Pierce Time 2
expires

1 = On
2 = On
3 = On
4 = Off

1 = On
2 = On
3 = On
4 = Off

1 = Off
2 = Off
3 = On
4 = Off

Staged Pierce Time 3
expires

1 = On
2 = On
3 = On
4 = On

Torch accelerates to cut

speed

1 = Off
2 = Off
3 = Off
4 = On

Torch accelerates to cut

speed

1 = Off
2 = Off
3 = Off
4 = On

Torch accelerates to cut

speed

At end of Staged
Pierce

All Staged Pierce outputs

remain on until the end of the

cut (M08)

Staged Pierce output 4

remains on until the end of the

cut (M08)

Staged Pierce output 4

remains on until the end of the

cut (M08)