Powermax diagnostic screen – Hypertherm V9 Series Phoenix Rev.11 User Manual
Page 168

168
Phoenix 9.76.0 Installation and Setup Manual 806410
7 – Plasma Setup
Powermax Diagnostic screen
The Powermax Diagnostic screen reports the status of several Powermax settings. Choose Setups > Diagnostics, then
choose the Powermax soft key.
Cut Mode: Shows the cut mode set by the CNC and sent to the Powermax (Normal, Continuous Pilot Arc [CPA], or
Gouge).
Set Arc Current: Shows the current level set by the CNC and sent to the Powermax.
Gas Pressure: Shows the gas pressure set by the CNC and sent to the Powermax. The CNC uses the gas pressure
from the cut chart or the part program.
Torch Lead Length: The CNC uses the torch lead length to determine the correct range for the gas pressure. The gas
pressure and lead lengths are stored in the Powermax65 and Powermax85 cut charts.
Control/DSP Revision: The firmware in the Powermax consists of two parts: the first is the control firmware and the
second is the DSP.
Arc On Time: The time that the Powermax has been on and producing an arc.
AC Input Voltage: The supply voltage as measured by the Powermax sensors.
DC Buss Voltage: The internal DC voltage as measured by the Powermax sensors.