Phoenix 9.76.0 Installation and Setup Manual 806410
7 – Plasma Setup
Serial communication interface
RS-422C connections to HPR CNC interface
Powermax plasma supply
Hypertherm CNCs support a serial connection to the Powermax65
®
, Powermax85
®
, and Powermax105
®
. From the CNC
you can set cut mode (normal cutting or continuous pilot arc), current, and gas pressure. A diagnostic screen helps you
monitor the status of the Powermax system.
Setting up a Powermax system in Phoenix requires the following steps:
Select the Powermax65 or Powermax85 in the Station Configuration screen.
Assign the Powermax to a serial port.
Assign I/O for the Powermax.
Selecting the Powermax in the Station Configuration screen
1. Choose Setups > Password and enter your password to open the Station Configuration screen.
2. For Station 1 (or the station you want to set up for the Powermax), choose your Powermax model from the drop-down
list.
Control (male)
Supply (male)
Signal name
DB-9 pin
Signal name
DB-37 pin
TxD-
2
RxD-
1
RxD-
3
TxD-
2
TxD+
4
RxD+ 20
RxD+
7