Device monitoring via SNMP

54 · G&D DVICenter

6. If you use the

SNMPv2c

protocol version, use the respective paragraph to enter the

same Community name as selected in the Network Management System.

7. If you decided to use the

SNMPv3

protocol version, use the respective paragraph to

enter the following data:

Log level:

Select from which severity level an SNMP trap is to be sent.
The selected severity level and all lower severity levels are

logged.

Version:

Select if the traps are to be created and sent according to the

SNMPv2c (v2c) or SNMPv3 (v3) protocol.

Notification type:

Select if the occurrences are sent as Trap or Inform packet.

IMPORTANT:

The transfer of the packet password (Community) of the SNMPv2c

protocol version is not encrypted. Therefore, it can be easily tapped!
If required, use the SNMPv3 protocol version (see below) and a high Security level

to ensure a secure data transfer.

User:

Enter the username for communication with the Network

Management System an.

Authentication pro-

tocol

Select the authentication protocol (

MD5

or

SHA

) which has

been activated in the Network Management System.

Authentication

passphrase

Enter the authentication passphrase for the communication

with the Network Management System.

Security level

Select between one of the following options:

NoAuthNoPriv:

deactivated user authentication and Privacy

protocol

AuthNoPriv:

activated user authentication, deactivated Pri-

vacy protocol

AuthPriv:

activated user authentication and Privacy protocol

Privacy protocol:

Select the privacy protocol (

DES

or

AES

) which has been

activated in the Network Management System.

NOTE:

If you select the 2 - Critical, severity level SNMP traps are sent for

occurrences from this level and from the 1 - Alarm and 0 - Emergency severity

levels.

NOTE:

Inform packets require a confirmation of the Network Management Sys-

tem. If this confirmation is not available, the transmission is repeated.