Getting started
G&D DVICenter · 19
In the default settings, ports
1
through
8
are pre-configured to connect user modules.
Ports
9
through
32
are pre-configured to connect target modules:
To change the assignment of Dynamic Ports, mind the following instructions:
Configure all 32 ports to connect either a user module
(CON)
or a target module
(CPU)
.
Configure at least one port to connect either a user module
(CON)
or a target mod-
ule
(CPU)
.
Configuring ports
You can configure the ports according to your preferences. When doing this, mind
the instructions described in the previous paragraph.
How to configure a port’s mode:
1. Click on the
Port configuration
icon (see figure on the right) in the toolbar of
the web application.
2. Right-click the port whose mode you want to change. Now, you can select the
mode from the context menu.
Figure 3: Default port assignment
ADVICE:
To facilitate the installation of the KVM switch, you can switch the port
LEDs to the port mode (see page 20).
ADVICE:
The graphic shows the port configuration.
In Standard mode, you can switch between
Up mode
and
Down mode
of the ports.
In Compatibility mode you can change the ports to connect user modules (
CON
mode
) and target modules (
CPU mode
).
NOTE:
You can select multiple ports with the left mouse key while pressing
Shift
or
Ctrl
.