Device monitoring via SNMP
G&D DVICenter · 53
7. Click
OK
to save your settings and to leave the window.
Configuring SNMP traps
How to add a new trap or edit an existing trap:
1. Use the tree view to click on
KVM matrix systems > [name] > Matrix switches
.
2. Right-click the device to be configured. Now click the
Configuration
entry in the
context menu.
3. Click the
Network > SNMP trap
tabs.
4. Click
Add
or
Edit
.
5. Enter the following data in the
Global
paragraph:
Engine ID method:
Select how the
SnmpEngineID
should be assigned:
Random:
The SnmpEngineID is re-assigned with every
restart of the device.
Fix:
The SnmpEngineID is the same as the MAC address of
the device’s network interface.
User:
The string entered under Engine ID is used as
SnmpEngineID.
Engine ID:
When using the Engine ID method
User
, enter a string that is
used as Engine ID.
Server:
Enter the IP address of the Network Management Servers.
Protocol:
Select the protocol (
TCP
or
UDP
) – normally UDP – via which
the SNMP packets are to be transmitted.
Port:
Define the port – normally 162 – on which the outgoing
SNMP packets are to be accepted.
Retries:
Enter the number of retries to send an SNMP Inform.
Timeout:
Enter the time (in seconds) after which an SNMP Inform is to
be sent again if you have received no confirmation.
NOTE:
Inputs are only possible if the Inform option has been selected in the
Notification type entry.
NOTE:
Inputs are only possible if the Inform option has been selected in the
Notification type entry.