Connecting analogue matrix switches (bridging), Operation, Dvicenter catcenter neo vga-cpu ucon – Guntermann & Drunck DVICenter DP16 Config Panel User Manual
Page 189
![background image](https://www.manualsdir.com/files/788354/content/doc189.png)
Connecting analogue matrix switches (Bridging)
G&D DVICenter · 187
Connecting analogue matrix switches
(Bridging)
As of firmware version 1.7.000 of the digital matrix switch
DVICenter
, you can inte-
grate analogue matrix switches of the
CATCenter NEO
series into the KVM matrix sys-
tem.
Operation
Using a
VGA-CPU
target module, the digital matrix switch
DVICenter
establishes a con-
nection to one of the
UCON
user modules connected to the analogue matrix switch
CATCenter NEO
.
The target module
VGA-CPU
is directly connected to the signal line of the user module
UCON
. The matrix switches communicate over a TCP/IP connection.
The digital matrix switch can use every established Bridge line to switch to any target
module of the analogue matrix switch.
The target modules of the analogue matrix switch are listed in the OSD and in the
web application of the digital matrix switch. Here, they can be configured (see
page 84 ff.) and grouped (see page 142 ff.).
Figure 1: Connection of a digital and an analogue matrix switch
EXAMPLE:
A user uses the OSD of the digital matrix switch
DVICenter
to access the
target
NEO-Target
connected to the analogue matrix switch
CATCenter NEO.
Over the TCP/IP connection, the digital matrix switch
DVICenter
transmits the
switching command to the analogue matrix switch
NEO
.
The digital matrix switch
DVICenter
switches the user to the target module
VGA-
CPU
of the Bridge line.
The analogue matrix switch
NEO
switches the computer ti the user module
UCON
of the Bridge line.
DVICenter
CATCenter
NEO
VGA-CPU
UCON