beautypg.com

Messages regarding critical statuses of devices, Viewing the list of critical devices – Guntermann & Drunck DVICenter DP16 Config Panel User Manual

Page 46

background image

Monitoring functions

44 · G&D DVICenter

3. Click the

Monitoring

tab.

Two tables list the monitoring values of the KVM system:

To give you a faster overview, the values are grouped in both columns.

4. Mark the monitoring values to be enabled/disabled.

5. Click the button (right arrow key) to disable the monitoring value or

(left arrow key) for enabling.

6. Click

OK

to save your settings.

Advanced function regarding the administration of

critical devices

The Critical Devices branch lists the devices that show at least one value that exceeds

the normal operating values.

Messages regarding critical statuses of devices

If one value exceeds the normal operating values, the branch is marked red. A blink-

ing message under the main view points to this condition.

Viewing the list of critical devices

How to view the list of critical devices:

1. Click on the

System monitoring > Critical Devices

folders in the tree view.

The main view lists all affected devices. The critical values are displayed in the table.

Enabled:

lists all active monitoring values.

Disabled:

lists all inactive monitoring values.

NOTE:

A sub-branch is displayed for each device class in the KVM system (e. g.

KVM matrix systems).

ADVICE:

If the blinking message appears on your screen, press

Ctrl+Space

to open

the Critical devices branch.
Click on the blinking message to show the list of the deviating values in a separate

window.

ADVICE:

Click a sub-branch of the folder in order to only list the devices of a

particular device class.