Firmware update – Guntermann & Drunck DVICenter DP16 Config Panel User Manual
Page 35
![background image](https://www.manualsdir.com/files/788354/content/doc035.png)
Basic configuration of the web application
G&D DVICenter · 33
How to select the SSL certificate you want to use:
1. Click the tools symbol in the toolbar.
2. Click the
Certificate
tab.
3. Select the certificate you want to use:
3. Click
OK
to close the window.
Firmware update
The firmware of each device can be easily updated via the web application.
How to update the firmware:
1. Open the web application of the device whose firmware you want to update.
2. Click the tools symbol in the toolbar.
3. Click the
Tools > Firmware update
tabs.
IMPORTANT:
Selecting and activating another certificate terminates all active ses-
sions of the web application.
G&D certificate #1:
This certificate is enabled for new devices.
G&D certificate #2:
This certificate is supported by all G&D devices with inte-
grated web application.
User certificate:
Select this option if you want to use a certificate purchased
from a certificate authority or if you want to use a user cer-
tificate.
Now you can import and upload the certificate:
1. Click
Import certificate from file
and use the file dialog to
select the .pem file you want to import.
You can also copy the plain text of the server certificate,
the server’s private key and the certificate of the certifi-
cate authority to the text box.
2. Click
Upload and activate
to store and activate the impor-
ted certificate for the device.
IMPORTANT:
This function only updates the firmware of the device on which the
web application has been started!
ADVICE:
Older devices do not support
certificate #1
. In this case use
certificate #2
or a
user certificate
.within the KVM system.