Altera Avalon Verification IP Suite User Manual
Page 75
Description
Legal
Values
Default
Value
Parameter
When On, the interface includes a
writeresponse
pin.
On/Off
Off
Use the writeresponse signal
When On, the interface includes a
readresponse
pin.
On/Off
Off
Use the readresponse signal
When On, the interface includes a
clken
pin.
On/Off
Off
Use the clken signals
Burst Attributes
When On, the address for bursts wraps instead of an
incrementing. With a wrapping burst, when the
address reaches a burst boundary, it wraps back to the
previous burst boundary. Consequently, only the low
order bits are used for addressing.
On/Off
On
Linewrap burst
When On, memory bursts are aligned to the address
size.
On/Off
On
Burst on burst boundaries
only
Miscellaneous
Specifies when a timeout occurs if
readdatavalid
is
not asserted.
N/A
100
Read response timeout
(cycles)
Specifies when a timeout occurs if a burst write transfer
has not completed.
N/A
100
Avalon write timeout (cycles)
Timeout period for the continuous assertion of
waitrequest
.
N/A
1024
Waitrequest timeout (cycles)
Specifies the maximum number of pipelined reads that
can be pending.
N/A
1
Maximum pending reads
Sets the read latency for fixed-latency slaves. Not used
on interfaces that include the
readdatavalid
signal.
N/A
0
Fixed read latency (cycles)
Specifies the maximum read latency in cycle for test
coverage function
N/A
100
Maximum read latency
(cycles)
Specifies the maximum wait time allowed for read
cycle for coverage.
N/A
100
Maximum waitrequest read
cycles (for coverage)
Maximum wait time allowed for write cycle for
coverage.
N/A
100
Maximum waitrequest write
cycles (for coverage)
Maximum continuous read time allowed for coverage.
N/A
5
Maximum continuous read
(cycles)
Maximum continuous write time allowed for coverage.
N/A
5
Maximum continuous write
(cycles)
Maximum continuous wait request time allowed for
coverage.
N/A
5
Maximum continuous
waitrequest (cycles)
Maximum continuous readdatavalid time allowed for
coverage.
N/A
5
Maximum continuous
readdatavalid (cycles)
For VHDL BFMs only. Use this option to assign a
unique number to each BFM in the testbench design.
0–1023
0
VHDL BFM ID
Timing
Altera Corporation
Avalon-MM Monitor
7-3