5
Avalon-MM Master BFM
Send Feedback
The Avalon-MM Master BFM implements the Avalon-MM interface protocol, including: read, write, burst
read, and burst write. The figure below shows the top-level modules for a testbench using the Avalon-MM
BFM to verify an Avalon-MM slave component. The typical testbench includes the folowing components:
• The Avalon-MM Master BFM
• A test program
• The DUT that includes an Avalon-MM slave interface
Using the Avalon-MM BFM created by Altera, third-party, has the following advantage. It highlights any
misinterpretation of the Avalon-MM protocol that might be missed in a testbench designed by a single
engineer.
The BFMs allow illegal transactions so that you can test the error-handling functionality of your
DUT. Consequently, the BFMs cannot be relied upon to guarantee protocol compliance. The Avalon
Monitor components verify protocol compliance.
Figure 5-1: Top-Level Module to Verify an Avalon-MM Slave Device
Avalon-MM
Master BFM
Avalon-MM
Slave Component
DUT
Testbench
Avalon-MM
Test Program
HDL
HDL
Note:
Related Information
©
2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words
and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other
words and logos identified as trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance of its semiconductor products to current specifications in accordance with
Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes
no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly
agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published
information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134