Parameters, Parameters -2 – Altera Avalon Verification IP Suite User Manual
Page 74
Parameters
The Avalon-MM Monitor supports the full range of signals defined for the Avalon-MM master and slave
interfaces. You can customize the Avalon-MM master and slave interfaces using the parameters described
in the following table.
Table 7-1: Parameters for the Avalon-MM Monitor
Description
Legal
Values
Default
Value
Parameter
Port Widths
Address width in bits.
N/A
32
Address width
Data symbol width in bits. The symbol width should
be 8 for byte-oriented interfaces.
N/A
8
Symbol width
Numbers of symbols per word.
N/A
4
Number of symbols
The width of the burst count in bits.
N/A
3
Burstcount width
Read response signal width in bits.
N/A
8
Readresponse width
Write response signal width in bits.
N/A
8
Writeresponse width
Port Enables
When On, the interface includes a
read
pin.
On/Off
On
Use the read signal
When On, the interface includes a
write
pin.
On/Off
On
Use the write signal
When On, the interface includes
address
pins.
On/Off
On
Use the address signal
When On, the interface includes
byte_enable
pins.
On/Off
On
Use the byte enable signal
When On, the interface includes
burstcount
pins.
On/Off
On
Use the burstcount signal
When On, the interface includes a
readdata
pin.
On/Off
On
Use the readdata signal
When On, the interface includes a
readdatavalid
pin.
On/Off
On
Use the readdatavalid signal
When On, the interface includes a
writedata
pin.
On/Off
On
Use the writedata signal
When On, the interface includes
writedata
pins.
On/Off
Off
Use the begintransfer signal
When On, the interface includes a
beginburst-
transfer
pins.
On/Off
Off
Use the beginbursttransfer
signal
When On, the interface includes a
waitrequest
pin.
On/Off
On
Use the waitrequest signal
When On, the interface includes an
arbiterlock
pin.
On/Off
Off
Use the arbiterlock signal
When On, the interface includes a
lock
pin.
On/Off
Off
Use the lock signal
When On, the interface includes a
debugaccess
pin.
On/Off
Off
Use the debugaccess signal
When On, the interface includes a
transactionid
pin.
On/Off
Off
Use the transactionid signal
Avalon-MM Monitor
Altera Corporation
Parameters
7-2