4 firmware/fpga update, Firmware/fpga update – Pilz PNOZ mm0p 24VDC User Manual
Page 69

Fieldbus modules
Operating Manual PNOZmulti communication interfaces
1001154-EN-13
69
Byte
Diag_Bit Content
2116
032
Configuration error
033
Fault in the application program
034
Periphery error
035
Fault on the speed monitor
036
Fault on the bus module
037
Internal self test error
038
Internal data error
039
Internal parameter error
2117
040
Internal serial/I2C error
041
Internal time error
042
Internal processor error
043
Internal compare error
044
Internal sequence error
045
Internal periphery error
046
Internal bus module error
047
Internal speed monitor error
Information
All error messages or status messages that come from the PNOZmulti can
overwrite each other. In particular, a PNOZmulti error message can be over-
written by a PNOZmulti status or error message without having to delete the
error explicitly (via S-0-0099).
Firmware/FPGA update
Update the firmware as follows:
1. Make sure that the PNOZ mc10p is in NRT status (no data traffic with the Master).
2. Copy the update file (*.kfu) into the web server's root directory via FTP or TFTP. The
file contains the firmware and the FPGA image.
3. Carry out a restart (power-on reset).
4. The firmware is updated on start-up. This takes approx. 1 minute. Do not interrupt this
process. Afterwards the PNOZ mc10p will restart. Please note that at this point, com-
munication between the PNOZmulti base unit and thePNOZ mc10p is interrupted (DI-
AG-LED flashes).
5. Carry out another restart (power-on reset) to restore the connection between the
PNOZmulti base unit and PNOZ mc10p.
4.5.4
- PNOZ mm0.1p PNOZ mm0.2p PNOZ mml1p PNOZ mml2p PNOZ mmc1p ETH PNOZ mmc2p seriell PNOZ mmc3p DP PNOZ mmc6p CAN PNOZ mmc4p DN PNOZ m1p base unit PNOZ m1p base unit coated version PNOZ m0p base unit not expandable PNOZ m2p base module press function PNOZ m3p base unit burner function PNOZ m1p ETH PNOZ m3p ETH PNOZ m0p ETH PNOZ m2p ETH PNOZ m1p ETH coated version PNOZ mi1p 8 input PNOZ mi1p 8 input coated version PNOZ mo1p 4 so PNOZ mo1p 4so coated version PNOZ mo3p 2so PNOZ mo2p 2n/o PNOZ mo2p 2n/o coated version PNOZ mo5p 4 n/o burner PNOZ mo4p 4n/o PNOZ mo4p 4n/o coated version PNOZ ml1p safe link 24VDC PNOZ ml2p safe link PDP PNOZ ms1p standstill / speed monitor PNOZ ms2p PNOZ ma1p 2 Analog Input PNOZ ms3p standstill / speed monitor PNOZms2p HTL PNOZ ma1p coated version PNOZ ml1p coated version PNOZ ms2p TTL coated version PNOZ ms3p HTL PNOZ ms2p TTL PNOZ ms3p TTL PNOZ mi2p 8 standard input PNOZ mc1p PNOZ mc1p coated version PNOZ mc0p Powersupply PNOZ mc5p Interbus PNOZ mc7p CC-Link coated version PNOZ mc7p CC-Link PNOZ mc6p CANopen coated version PNOZmc5.1p Interbus LWL / Fiberoptic PNOZ mc4p DeviceNet coated version PNOZ mc8p Ethernet IP / Modbus TCP PNOZ mc9p Profinet IO PNOZ mc3p Profibus 2 PNOZ mc8p coated version PNOZ mc6p CANopen 2 PNOZ mc4p DeviceNet 2 PNOZ mc2.1p EtherCAT 2 PNOZ mc10p SERCOS III PNOZ mc7p CC-Link 2 PNOZ mc6.1p CANopen 3