beautypg.com

8 diagnostic word, 1 introduction, 2 elements with diagnostic word – Pilz PNOZ mm0p 24VDC User Manual

Page 128: Section 8, Diagnostic word, Introduction, Elements with diagnostic word, Diag, Nostic word, And the online

background image

Diagnostic word

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

128

Diagnostic word

Introduction

A diagnostic word can be read out for those elements in the PNOZmulti Configurator that
can store a status. The diagnostic word contains information on a particular element, such
as:

}

Operating states (e.g. safety gate was opened)

}

Error messages (e.g. N/C contact failed to switch or switched too late)

Elements with diagnostic word

The diagnostic word is accessed by activating an Element ID. The permitted value range
for the Element ID is 1 ... 100. Elements with an element ID include:

}

Function elements

– E-STOP and safety gate
– Safety gate with guard locking
– Light curtain
– Enabling switch
– Foot switch
– Pressure sensitive mat
– Two-hand button
– Operating mode selector switch
– Analogue input module

}

Cascading

– Cascading input
– Cascading output

}

Logic elements

– RS flip-flop
– Start element

}

Speed monitor

}

Press elements

– Run monitoring
– Rotary cam arrangement
– Monitoring
– Set-up mode
– Single-stroke
– Automatic
– Light curtain

}

Burner element

8

8.1

8.2