Pilz PNOZ mm0p 24VDC User Manual
Page 133

Diagnostic word
Operating Manual PNOZmulti communication interfaces
1001154-EN-13
133
}
Two-hand pushbuttons
Bit Message
Comment
1
Two-hand button must be operated.
Switches are in their start position.
4
Pushbutton 1 or 2 was operated too late.
Simultaneity was exceeded.
5
Pushbutton 1 or 2 was not operated.
One of the pushbuttons was operated too
late or was not operated at all. Or one of the
pushbuttons was operated and then re-
leased.
6
Two-hand button is deactivated.
Deactivation input is configured and =1
8
Error in the test pulse wiring.
}
Operating mode selector switch
Bit Message
Comment
5
The input signals at the operating mode selector switch
are faulty
No input is “1”.
8
Error in the test pulse wiring.
}
Analogue input module
Bit Message
Comment
2
Analogue input module is ready for reset
Manual or monitored reset was configured.
The reset button has not yet been operated.
3
Tolerance between input I0 and I1 has been exceeded
The configured permitted deviation between
the measured values for i0 and i1 has been
exceeded.
4
Range limit R1 has been violated.
The value is above or below the configured
range limit.
5
Range limit R2 has been violated.
6
Range limit R3 has been violated.
7
Range limit R4 has been violated.
8
Threshold value monitoring for the threshold L1 has
been activated (Status =1).
9
Threshold value monitoring for the threshold L2 has
been activated (Status =1).
10 Threshold value monitoring for the threshold L3 has
been activated (Status =1).
11 Threshold value monitoring for the threshold L4 has
been activated (Status =1).
12 Threshold value monitoring for the threshold L5 has
been activated (Status =1).
13 Threshold value monitoring for the threshold L6 has
been activated (Status =1).
- PNOZ mm0.1p PNOZ mm0.2p PNOZ mml1p PNOZ mml2p PNOZ mmc1p ETH PNOZ mmc2p seriell PNOZ mmc3p DP PNOZ mmc6p CAN PNOZ mmc4p DN PNOZ m1p base unit PNOZ m1p base unit coated version PNOZ m0p base unit not expandable PNOZ m2p base module press function PNOZ m3p base unit burner function PNOZ m1p ETH PNOZ m3p ETH PNOZ m0p ETH PNOZ m2p ETH PNOZ m1p ETH coated version PNOZ mi1p 8 input PNOZ mi1p 8 input coated version PNOZ mo1p 4 so PNOZ mo1p 4so coated version PNOZ mo3p 2so PNOZ mo2p 2n/o PNOZ mo2p 2n/o coated version PNOZ mo5p 4 n/o burner PNOZ mo4p 4n/o PNOZ mo4p 4n/o coated version PNOZ ml1p safe link 24VDC PNOZ ml2p safe link PDP PNOZ ms1p standstill / speed monitor PNOZ ms2p PNOZ ma1p 2 Analog Input PNOZ ms3p standstill / speed monitor PNOZms2p HTL PNOZ ma1p coated version PNOZ ml1p coated version PNOZ ms2p TTL coated version PNOZ ms3p HTL PNOZ ms2p TTL PNOZ ms3p TTL PNOZ mi2p 8 standard input PNOZ mc1p PNOZ mc1p coated version PNOZ mc0p Powersupply PNOZ mc5p Interbus PNOZ mc7p CC-Link coated version PNOZ mc7p CC-Link PNOZ mc6p CANopen coated version PNOZmc5.1p Interbus LWL / Fiberoptic PNOZ mc4p DeviceNet coated version PNOZ mc8p Ethernet IP / Modbus TCP PNOZ mc9p Profinet IO PNOZ mc3p Profibus 2 PNOZ mc8p coated version PNOZ mc6p CANopen 2 PNOZ mc4p DeviceNet 2 PNOZ mc2.1p EtherCAT 2 PNOZ mc10p SERCOS III PNOZ mc7p CC-Link 2 PNOZ mc6.1p CANopen 3