Fieldbus modules

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

44

Index 2003
This index contains the state of the inputs/outputs plus the LED status

Sub-In-

dex (dec) Content

Example/Comment

1

I0 ... I7 base unit,
IM0 ... I7 base unit Mini

For example: The safety system consists of one base unit PNOZ

m1p and one expansion module PNOZ mi1p
Assignment of Bytes on the base units PNOZmulti

2

I8 ... I15 base unit,
I8 ... I15 base unit Mini

3

I16 ... I19 base unit
IM16 ... IM19 base unit Mini

4

0

5

0

6

I0 ... I7 1st expansion mod-

ule, right

Sub-Index 1: PNOZ m1p

7

I0 ... I7 2nd expansion mod-

ule, right

I7

I6

I5

I4

I3

I2

I1

I0

8

I0 ... I7 3rd expansion mod-

ule, right

Sub-Index 2: PNOZ m1p

9

I0 ... I7 4th expansion mod-

ule, right

I15

I14

I13

I12

I11

I10

I9

I8

10

I0 ... I7 5th expansion mod-

ule, right

Sub-Index 3: PNOZ m1p

11

I0 ... I7 6th expansion mod-

ule, right

0

0

0

0

I19

I18

I17

I16

12

I0 ... I7 7th expansion mod-

ule, right

Sub-Index 4:

13

I0 ... I7 8th expansion mod-

ule right

0

0

0

0

0

0

0

0

Sub-Index 5:
0

0

0

0

0

0

0

0

Sub-Index 6: PNOZ mi1p
I7

I6

I5

I4

I3

I2

I1

I0

If an input has a high signal, the corresponding bit will be "1"; if an

input has a low signal, the bit will be "0".

4.3.3.3