Error codes on Modbus TCP
Code
Name
Description
01
Invalid function
The PNOZ mc8p does not support the func-
tion code in the enquiry.
02
Invalid data address
The data address received in the enquiry is
outside the memory range.
03
Invalid data
Invalid data requested.
Web interface for commissioning and testing
A Pilz web interface can be used when commissioning or as a testing aid. It can be used to
poll data from the PNOZmulti.
}
Commission a base unit and PNOZ mc8p as described in the operating instructions.
}
Connect the PNOZ mc8p to the PC.
}
Enter the IP address (URL) in your browser's address bar,
e.g.: http://172.16.216.139
}
The input mask provides access to the inputs and outputs on the PNOZmulti system
and to the table segments.
Restricting access
In principle, each Ethernet subscriber can set up a connection to the PNOZ mc8p. This ac-
cess can be restricted.
}
To establish a connection to the FTP site, enter the IP address (URL) of the
PNOZ mc8p in your browser's address bar.
A login window appears.
}
Log in to gain access to the user range of the PNOZ mc8p.
The default access data is: User name: User
Password: Password
}
Save the file ip_access.cfg on your PC and open it using an editor. Once opened the
file contains the following information:
[MODBUS/TCP]
*.*.*.*
[Ethernet/IP]
*.*.*.*
If
*.*.*.* is entered, all subscribers will have unrestricted access.
}
Instead of the characters
*.*.*.*, enter the IP addresses of the subscribers to which you
wish to grant restricted access, e.g.:
[MODBUS/TCP]
172.16.205.24
172.16.205.40
[Ethernet/IP]
172.16.205.96
4.4.8
4.4.9
- PNOZ mm0.1p PNOZ mm0.2p PNOZ mml1p PNOZ mml2p PNOZ mmc1p ETH PNOZ mmc2p seriell PNOZ mmc3p DP PNOZ mmc6p CAN PNOZ mmc4p DN PNOZ m1p base unit PNOZ m1p base unit coated version PNOZ m0p base unit not expandable PNOZ m2p base module press function PNOZ m3p base unit burner function PNOZ m1p ETH PNOZ m3p ETH PNOZ m0p ETH PNOZ m2p ETH PNOZ m1p ETH coated version PNOZ mi1p 8 input PNOZ mi1p 8 input coated version PNOZ mo1p 4 so PNOZ mo1p 4so coated version PNOZ mo3p 2so PNOZ mo2p 2n/o PNOZ mo2p 2n/o coated version PNOZ mo5p 4 n/o burner PNOZ mo4p 4n/o PNOZ mo4p 4n/o coated version PNOZ ml1p safe link 24VDC PNOZ ml2p safe link PDP PNOZ ms1p standstill / speed monitor PNOZ ms2p PNOZ ma1p 2 Analog Input PNOZ ms3p standstill / speed monitor PNOZms2p HTL PNOZ ma1p coated version PNOZ ml1p coated version PNOZ ms2p TTL coated version PNOZ ms3p HTL PNOZ ms2p TTL PNOZ ms3p TTL PNOZ mi2p 8 standard input PNOZ mc1p PNOZ mc1p coated version PNOZ mc0p Powersupply PNOZ mc5p Interbus PNOZ mc7p CC-Link coated version PNOZ mc7p CC-Link PNOZ mc6p CANopen coated version PNOZmc5.1p Interbus LWL / Fiberoptic PNOZ mc4p DeviceNet coated version PNOZ mc8p Ethernet IP / Modbus TCP PNOZ mc9p Profinet IO PNOZ mc3p Profibus 2 PNOZ mc8p coated version PNOZ mc6p CANopen 2 PNOZ mc4p DeviceNet 2 PNOZ mc2.1p EtherCAT 2 PNOZ mc10p SERCOS III PNOZ mc7p CC-Link 2 PNOZ mc6.1p CANopen 3