1 example, 5 compilation of the diagnostic words, Example – Pilz PNOZ mm0p 24VDC User Manual
Page 131: Compilation of the diagnostic words, Chapter

Diagnostic word
Operating Manual PNOZmulti communication interfaces
1001154-EN-13
131
Example
Safety gate with Element ID = 5:
}
Dual-channel
}
Manual reset
}
Start-up test
Evaluation of the following bits:
}
Bit 2 = 1: Safety gate is ready for reset. The reset button for manual reset must be oper-
ated.
}
Bit 8 = 1: Error in the test pulse wiring
0000 0000 0000 0000
PNOZmulti Configurator
0000 0000 0000 1000
0000 0000 0010 0000
0000 0000 0100 0000
0000 0000 1000 0000
0000 0001 0000 0000 Error in the test pulse wiring
0000 0010 0000 0000
0000 0100 0000 0000
0000 1000 0000 0000
0001 0000 0000 0000 There is a 1 signal at input 1.
0010 0000 0000 0000 There is a 1 signal at input 2.
0100 0000 0000 0000 There is a 1 signal at input 3.
1000 0000 0000 0000 There is a 1 signal at input 4.
Evaluate Bit 2 of the diagnostic
word logic element for ID = 5
within the user program
Poll diagnostic word for ID = 5
via interface
Poll diagnostic word for ID = 5
via fieldbus module
Display Bit 2 and 8 of the
safety gate function element for
ID = 5 (e.g. PMImicro diag)
Bit 2
Bit 8
0000 0000 0000 0010
Safety gate is ready for reset
0000 0000 0000 0001
Safety gate has been opened
0000 0000 0000 0100
Function test must be performed
0000 0000 0001 0000
N/C contact failed to switch or switched too late
Enable issued
Compilation of the diagnostic words
In the following tables, the respective bit =1 when the corresponding message applies. If no
bit = 1, i.e. data word DW = 0, then no error is present.
Exception: On some function elements the state of the input signals is polled. The corre-
sponding bit =1 without an error being present.
Information
If you are using PVIS expanded diagnostics, you will receive additional in-
formation (actions) on your display unit alongside the diagnostic word.
Please also refer to the explanations regarding element configuration in the
PNOZmulti Configurator's online help.
8.4.1
8.5
- PNOZ mm0.1p PNOZ mm0.2p PNOZ mml1p PNOZ mml2p PNOZ mmc1p ETH PNOZ mmc2p seriell PNOZ mmc3p DP PNOZ mmc6p CAN PNOZ mmc4p DN PNOZ m1p base unit PNOZ m1p base unit coated version PNOZ m0p base unit not expandable PNOZ m2p base module press function PNOZ m3p base unit burner function PNOZ m1p ETH PNOZ m3p ETH PNOZ m0p ETH PNOZ m2p ETH PNOZ m1p ETH coated version PNOZ mi1p 8 input PNOZ mi1p 8 input coated version PNOZ mo1p 4 so PNOZ mo1p 4so coated version PNOZ mo3p 2so PNOZ mo2p 2n/o PNOZ mo2p 2n/o coated version PNOZ mo5p 4 n/o burner PNOZ mo4p 4n/o PNOZ mo4p 4n/o coated version PNOZ ml1p safe link 24VDC PNOZ ml2p safe link PDP PNOZ ms1p standstill / speed monitor PNOZ ms2p PNOZ ma1p 2 Analog Input PNOZ ms3p standstill / speed monitor PNOZms2p HTL PNOZ ma1p coated version PNOZ ml1p coated version PNOZ ms2p TTL coated version PNOZ ms3p HTL PNOZ ms2p TTL PNOZ ms3p TTL PNOZ mi2p 8 standard input PNOZ mc1p PNOZ mc1p coated version PNOZ mc0p Powersupply PNOZ mc5p Interbus PNOZ mc7p CC-Link coated version PNOZ mc7p CC-Link PNOZ mc6p CANopen coated version PNOZmc5.1p Interbus LWL / Fiberoptic PNOZ mc4p DeviceNet coated version PNOZ mc8p Ethernet IP / Modbus TCP PNOZ mc9p Profinet IO PNOZ mc3p Profibus 2 PNOZ mc8p coated version PNOZ mc6p CANopen 2 PNOZ mc4p DeviceNet 2 PNOZ mc2.1p EtherCAT 2 PNOZ mc10p SERCOS III PNOZ mc7p CC-Link 2 PNOZ mc6.1p CANopen 3