beautypg.com

10 current state of the virtual inputs – Pilz PNOZ mm0p 24VDC User Manual

Page 114

background image

Modbus/TCP

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

114

Byte 2

24

23

22

21

20

19

18

17

...
Byte 10

88

87

86

85

84

83

82

81

Byte 11

96

95

94

93

92

91

90

89

Byte 12

-

-

-

-

100

99

98

97

Register 1071 to 1126 "Element type"
Please refer to the chapter entitled

Element types [

173]

in the Appendix

Current state of the virtual inputs
The table below describes the Modbus/TCP data areas that contain the current state of the
virtual inputs. These are the virtual inputs that can be set by various subscribers (e.g. fieldbus).
Relevant areas for the data are defined in the Modbus/TCP data areas Discrete Inputs (1x)
and Input Register (3x). Read access is available to these data areas.

Register
(3x)

Coil/
Discrete Input
(1x)

Content

High Byte

Low Byte

1127

18047... 18032 Inputs, feedback status

0...15

i15…i8

i7…i0

1128

18063... 18048 Inputs, feedback status

16...31

i31…i24

i23…i16

1129

18079... 18064 Inputs, feedback status

32...47

i47…i40

i39…i32

1130

18095... 18080 Inputs, feedback status

48...63

i63…i56

i55…i48

1131

18111... 18096 Inputs, feedback status

64...79

i79…i72

i71…i64

1132

18127... 18112 Inputs, feedback status

80...95

i95…i88

i87…i80

1133

18143... 18128 Inputs, feedback status

96...111

i111…i104

i103…i96

1134

18159... 18144 Inputs, feedback status

112...127

i127…i120

i119…i112

1135

18175... 18160 Reserved

1136

18191... 18176 Reserved

1137

18207... 18192 Reserved

1138

18223... 18208 Reserved

1139

18239... 18224 Reserved

1140- 2047

Reserved

6.4.4.10