Safe Ethernet connection
The table below describes the Modbus/TCP data areas that contain the data for the safe
Ethernet connection. A description of how to use this data is provided in the chapter entitled
"Safe Ethernet Connection".
Register
(3x)
Coil/
Discrete Input
(1x)
Content
High Byte
Low Byte
20000 - 20017 -
Safe Ethernet connection
send data
21000 - 21017 -
Safe Ethernet connection
receive data
Updating the data areas
Data is updated with varying priority.
The table below shows the typical update cycles for the various data.
Content
Typ. update cycle
Virtual inputs/outputs
20 ms
Configuration
Once during initialisation
State of the inputs/outputs from the base unit and expan-
sion modules
320 ms
LED status
1000 ms
Number of elements that can store a state
Once during initialisation
Element enable
320 ms
Diagnostic words
1000 ms
Element types
Once during initialisation
Current state of the virtual inputs
1000 ms
Information
The update time may increase if there are additional TCP/IP connections
(e.g. PNOZmulti Configurator, PMI, control system) on the PG port (Port
9000).
6.4.4.13
6.4.5
- PNOZ mm0.1p PNOZ mm0.2p PNOZ mml1p PNOZ mml2p PNOZ mmc1p ETH PNOZ mmc2p seriell PNOZ mmc3p DP PNOZ mmc6p CAN PNOZ mmc4p DN PNOZ m1p base unit PNOZ m1p base unit coated version PNOZ m0p base unit not expandable PNOZ m2p base module press function PNOZ m3p base unit burner function PNOZ m1p ETH PNOZ m3p ETH PNOZ m0p ETH PNOZ m2p ETH PNOZ m1p ETH coated version PNOZ mi1p 8 input PNOZ mi1p 8 input coated version PNOZ mo1p 4 so PNOZ mo1p 4so coated version PNOZ mo3p 2so PNOZ mo2p 2n/o PNOZ mo2p 2n/o coated version PNOZ mo5p 4 n/o burner PNOZ mo4p 4n/o PNOZ mo4p 4n/o coated version PNOZ ml1p safe link 24VDC PNOZ ml2p safe link PDP PNOZ ms1p standstill / speed monitor PNOZ ms2p PNOZ ma1p 2 Analog Input PNOZ ms3p standstill / speed monitor PNOZms2p HTL PNOZ ma1p coated version PNOZ ml1p coated version PNOZ ms2p TTL coated version PNOZ ms3p HTL PNOZ ms2p TTL PNOZ ms3p TTL PNOZ mi2p 8 standard input PNOZ mc1p PNOZ mc1p coated version PNOZ mc0p Powersupply PNOZ mc5p Interbus PNOZ mc7p CC-Link coated version PNOZ mc7p CC-Link PNOZ mc6p CANopen coated version PNOZmc5.1p Interbus LWL / Fiberoptic PNOZ mc4p DeviceNet coated version PNOZ mc8p Ethernet IP / Modbus TCP PNOZ mc9p Profinet IO PNOZ mc3p Profibus 2 PNOZ mc8p coated version PNOZ mc6p CANopen 2 PNOZ mc4p DeviceNet 2 PNOZ mc2.1p EtherCAT 2 PNOZ mc10p SERCOS III PNOZ mc7p CC-Link 2 PNOZ mc6.1p CANopen 3