beautypg.com

Pilz PNOZ mm0p 24VDC User Manual

Page 139

background image

Diagnostic word

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

139

Bit/

DW

Message

Comment

Bit 10 Cannot switch on because the safety enable (“EN3”)

has not been triggered.

No enable because there is no safety ena-

ble EN3 = 0

Bit 11 Press was stopped because the static enable (“EN1”)

is missing.

No enable because static enable EN1 = 0

during operation

Bit 12 Safety enable (“EN3”) is missing.

No enable because safety enable EN3 = 0

during operation

}

Press element: Automatic mode

Bit/

DW

Message

Comment

DW =

0

“Automatic” mode has been enabled

Bit 0

"Automatic" mode is not active.

Enable has not been triggered, input param-

eter MODE = 0

Bit 2

Press is ready for reset.

1/0 pulse edge at Reset input parameter

Bit 8

Cannot switch on because the start enable (“EN2”)

has not been triggered.

No enable because start enable EN2 = 0

Bit 9

Cannot switch on because the static enable (“EN1”)

has not been triggered.

No enable because static enable EN1 = 0

Bit 11 Press was stopped because the static enable (“EN1”)

is missing.

No enable because static enable EN1 = 0

during operation

Bit 13 Cannot switch on because the stop button has been

operated.

No enable because input parameter STOP

= 0

}

Press element: Light curtain

Bit/

DW

Message

Comment

DW =

0

“Break” mode has been enabled

Bit 0

"Break" mode is inactive.

Enable has not been triggered, input param-

eter MODE = 0

Bit 2

Light curtain is ready for break mode.

Break mode is active, waiting for break

Bit 8

Enable must be performed.

1/0 pulse edge at Reset input parameter,

wait for reset

}

Burner part 1

Bit Message

Comment

2

Burner is ready for reset.

4

Stop (Signal=1 during start-up test)

5

Reset (Signal=1 during start-up test)

6

Safety chain 1 broken (CHA1)