Safe Ethernet connection

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

125

Communication partner 1

Block/Element

Safe Ethernet Connection

Local address
Remote address

20
21

Communication partner 2

Block/Element

Safe Ethernet Connection

Local address
Remote address

21
20

Point-to-point

connection

Fig.: Connection addresses on a point-to-point connection

Example 2: Connection addresses on multiple point-to-point connections with safe

Ethernet connection

}

Communication partner 1 maintains a point-to-point connection with communication

partners 2 and 3. A total of four different connection addresses are needed for the two
point-to-point connections. In the example, connection addresses 30 and 31 are to be
used for point-to-point connection 1 and addresses 40 and 41 for point-to-point connec-
tion 2.

}

Other potential connections in the network may no longer use connection addresses

30, 31, 40 and 41.

Communication partner 1

Block/Element

Safe Ethernet Connection

Local address
Remote address

30
31

Communication partner 2

Block/Element

Safe Ethernet Connection

Local address
Remote address

31
30

Point-to-point

connection 1

Block/Element

Safe Ethernet Connection

Local address
Remote address

40
41

Communication partner 3

Block/Element

Safe Ethernet Connection

Local address
Remote address

41
40

Point-to-point

connection 2

Fig.: Connection addresses on two point-to-point connections