beautypg.com

Pilz PNOZ mm0p 24VDC User Manual

Page 45

background image

Fieldbus modules

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

45

Sub-In-

dex (dec) Content

Example/Comment
INFORMATION:
On the base units PNOZmulti Mini, the status of the configurable

inputs/outputs is only displayed if they are configured as inputs in

the PNOZmulti Configurator.

Assignment of Bytes on the base units PNOZmulti Mini:
Sub-Index 1: PNOZ mmxp
I7

I6

I5

I4

IM3

IM2

IM1

IM0

Sub-Index 2: PNOZ mmxp
I15

I14

I13

I12

I11

I10

I9

I8

Sub-Index 3: PNOZ mmxp
0

0

0

0

IM19

IM18

IM17

IM16

14 ... 16

Reserved

17

LED I0 ... I7 base unit

For example: The safety system consists of one base unit PNOZ

m1p and one expansion module PNOZ mi1p

18

LED I8 ... I15 base unit

19

LED I16 ... I19 base unit

20

0

Sub-Index 17: PNOZ m1p

21

0

I7

I6

I5

I4

I3

I2

I1

I0

22

LED I0 ... I7
1st expansion module, right

Sub-Index 18: PNOZ m1p
I15

I14

I13

I12

I11

I10

I9

I8

23

LED I0 ... I7
2nd expansion module, right

Sub-Index 19: PNOZ m1p
0

0

0

0

I19

I18

I17

I16

24

LED I0 ... I7
3rd expansion module, right

Sub-Index 20:
0

0

0

0

0

0

0

0

25

LED I0 ... I7
4th expansion module, right

Sub-Index 21
0

0

0

0

0

0

0

0

26

LED I0 ... I7
5th expansion module, right

Sub-Index 22: PNOZ mi1p
I7

I6

I5

I4

I3

I2

I1

I0

27

LED I0 ... I7
6th expansion module, right

28

LED I0 ... I7
7th expansion module, right

29

LED I0 ... I7
8th expansion module, right

30 ... 32