Trigger Input Settings

This sets the measurement method, input polarity and the input time constant for the N-410
trigger input signal.

Measurement method

• Level synchronization

Data is read while the trigger input is on.

• One-shot synchronization

Once trigger input has been detected, data is read for a specified time (100 to 2500 ms).

Input polarity

Select the polarity of the trigger input.

• Norm. open

Norm. close

Input time constant

Select one of the following two input time constants.

• 2 ms

10 ms

Trigger input on/off command

Set the commands for command control of read operations (trigger input ON/OFF). This can be set to
any string of up to eight characters. However, it is recommended that you use the default
settings. The default settings are as follows.

• Trigger input on command: LON
• Trigger input off command: LOFF

Trigger input

*Read error

Communication
output

Read

Trigger input

*Read error

Measurement time

Measurement time

Communication
output

Read