Details of direct control commands, Details of direct control commands -9, Batch registration of id numbers – KEYENCE N-410 User Manual
Page 105: Batch check of id numbers, Individual registration of id numbers, Individual check of id numbers, Registration of serial id numbers, Check of serial id numbers, Saving a registered id number
6-9
6-4
Direct Control Command of the N-410 Series
S
6
Details of Direct Control Commands
Registering and checking an ID number for auto-polling.
A direct control command allows for registering and checking an ID number for auto-polling.
* Register a slave type to connect by using a setting command beforehand.
Batch registration of ID numbers
Command sent
: ID00nnnnnnnn···
Response
: OK
Explanation
: n = 0: Do not register
1: Register
* nnnn are the ID numbers between from 1 to 31 in sequence
Batch check of ID numbers
Command sent
: IDCHK
Response
: nnnnnnnn···
Explanation
: n = 0: Not registered
1: Registered
* nnnn are the ID numbers between from 1 to 31 in sequence
Individual registration of ID numbers
Command sent
: IDmmn
Response
: OK
Explanation
: mm = 01 to 31: ID number
n
= 0: Do not register
1: Register
Individual check of ID numbers
Command sent
: IDCHKmm
Response
: OK
Explanation
: mm = 01 to 31: ID number
n
= 0: Not registered
1: Registered
Registration of serial ID numbers
Command sent
: IDMAXmm
Response
: OK
Explanation
: mm = 00: Do not register serial ID numbers
01 to 31: ID number
All ID numbers after mm are registered.
Check of serial ID numbers
Command sent
: IDMAX
Response
: MAXmm
Explanation
: mm = 00: Not registered
01 to 31: ID number
99: Registered ID numbers are not serial numbers
Saving a registered ID number
Command sent
: IDSAVE
Response
: OK
Explanation