beautypg.com

4 main device display, Main device display, Status display  error display – KEYENCE N-410 User Manual

Page 148

background image

A-12

A

p

p

endi
ces

4

Main Device Display

The N-410 has the following displays.

Status display

Error display

Display

Status

Explanation

00

Lit

Normal operation

Flashing

Communication abnormality

01 to 31

Lit

• Connection confirmation test running (communication

normal)

• Specific ID polling (normal operation)

Flashing

• Displaying abnormal ID from connection confirmation

test

• Specific ID polling (abnormal communication)

88

Lit

Operating in multi-head Mode

50

Lit

Communication being initialized

51

Lit

Connection confirmation test mode running

52

Lit

Connected device confirmation test mode running

55

Lit

Making settings

Display

Contents

Explanation

98

RS-232C abnormality

RS-232C communication is slow, causing an overflow of
output data. Turn the power off then turn it on again. If the
condition does not resolve itself, the communication with
the host computer must be made faster.

97

Setting storage error

There is an error in the EEPROM memory. Press the test
switch to clear the error.

96

Buffer overflow

The N-410 send buffer has overflowed. Press the test
switch, send an "OVCLR" command from the host
computer or use the PLC to specify "Error clear".

95

Network error

This is an error in the network. Confirm that each of the ID
numbers is unique. If the ID numbers are set correctly, the
error may be due to transmission noise. Eliminate the
source of this noise.

94

PLC link error

This is displayed when communication is faulty over a PLC
link. Press the test switch to clear the error.