4 main device display, Main device display, Status display error display – KEYENCE N-410 User Manual
Page 148

A-12
A
4
Main Device Display
The N-410 has the following displays.
Status display
Error display
Display
Status
Explanation
00
Lit
Normal operation
Flashing
Communication abnormality
01 to 31
Lit
• Connection confirmation test running (communication
normal)
• Specific ID polling (normal operation)
Flashing
• Displaying abnormal ID from connection confirmation
test
• Specific ID polling (abnormal communication)
88
Lit
Operating in multi-head Mode
50
Lit
Communication being initialized
51
Lit
Connection confirmation test mode running
52
Lit
Connected device confirmation test mode running
55
Lit
Making settings
Display
Contents
Explanation
98
RS-232C abnormality
RS-232C communication is slow, causing an overflow of
output data. Turn the power off then turn it on again. If the
condition does not resolve itself, the communication with
the host computer must be made faster.
97
Setting storage error
There is an error in the EEPROM memory. Press the test
switch to clear the error.
96
Buffer overflow
The N-410 send buffer has overflowed. Press the test
switch, send an "OVCLR" command from the host
computer or use the PLC to specify "Error clear".
95
Network error
This is an error in the network. Confirm that each of the ID
numbers is unique. If the ID numbers are set correctly, the
error may be due to transmission noise. Eliminate the
source of this noise.
94
PLC link error
This is displayed when communication is faulty over a PLC
link. Press the test switch to clear the error.