Auto polling control, Turns on auto-polling, Turns on auto-polling for a specific id – KEYENCE N-410 User Manual
Page 106: Checks auto-polling, Turns off auto-polling, Specifying an id that a command is sent, Unspecifying an id number that a command is sent
![background image](/manuals/658143/106/background.png)
6-10
S
6
6-4
Direct Control Command of the N-410 Series
Auto polling control
Starts or quits auto-polling.
Turns on auto-polling
Command sent
: POLE00
Response
: OK
Turns on auto-polling for a specific ID
Command sent
: POLEmm
Response
: MAXmm
Explanation
: mm = 01 to 31: ID number
Auto-polling operates only for ID numbers specified for mm. When a large
amount of data is continuously sent, if polling operates on multiple ID
numbers, a buffer overflow may occur due to insufficient time for processing.
Use auto-polling for specific ID numbers when dealing with a large amount of
data.
Checks auto-polling
Command sent
: POLE
Response
: mm
Explanation
: mm = 00
: Auto-polling is on
01 to 31 : Auto-polling for only ID number mm.
OFF
: Auto-polling is off
Turns off auto-polling
Command sent
: POFF
Response
: OK
Explanation
: Turns off auto-polling.
Moves to manual polling mode by sending this command.
Hotline commands (Specifying an ID that a command is sent)
When sending operational commands to a BL/SR/RF Series device via the N-410 Series, usually
an ID number is added. It is possible to send operational commands without adding the ID
number of a specified BL/SR/RF Series device by sending the following command.
Make sure to cancel the setting after using the hotline command.
Specifying an ID that a command is sent
Command sent
: TRCOMmm
Response
: OK
Explanation
: mm = 01 to 31: ID number
Unspecifying an ID number that a command is sent
Command sent
: TROFF
Response
: OK
Check the specified an ID number that a command is sent
Command sent
: TRCOM
Response
: mm
Explanation
: mm = 00: An ID is not specified
01 to 31: ID number