Installing and wiring the input and output jacks, Wiring the trigger input – KEYENCE N-410 User Manual
Page 50
2-28
Inst
allatio
2
2-6
BL-U1 Connections and Wiring
Installing and Wiring the Input and Output Jacks
* These appear in this order from left to right on the terminal.
• Use M3.0 screws for the terminal.
• The wiring should use crimp contacts as shown below.
Wiring the trigger input
The trigger input is used to cause a BL/SR/RF Series device to begin reading.
The trigger input interval is on when 8.5 to 30 V DC is input.
The BL-U1 sensor power source can be used as the input power source.
Symbol
Explanation
Signal direction
TIM
Trigger input
Input
Input
+12 V OUT-
Sensor power source + side (+12 V DC, 300 mA)
Output
Sensor power source + side (0 V)
Output
COM
OK/NG output common
-
OK
OK output
Output
NG
NG output
Output
SDA
RS-422A data sending + side / RS-485 + side
Output/ input-
output
SDB
RS-422A data sending - side / RS-485 - side
Output/ input-
output
SG
Signal ground
-
RDA
RS-422A data reception + side
Input
RDB
RS-422A data reception - side
Input
TIM
Trigger input Sensor power source
(12 V DC, 300 mA)
OK/NG output
RS-422A/RS-485
+12V
OUT-
COM
OK
NG
SDA
SDB
SG
RDA
PDB
Round type
6.0 mm max.
Fork type
6.0 mm max.
+
+
Contact or
non-contact
8.5 to 30V DC
TIM
+12V
OUT–