beautypg.com

Installing and wiring the input and output jacks, Wiring the trigger input – KEYENCE N-410 User Manual

Page 50

background image

2-28

Inst
allatio

n

2

2-6

BL-U1 Connections and Wiring

Installing and Wiring the Input and Output Jacks

* These appear in this order from left to right on the terminal.

• Use M3.0 screws for the terminal.
• The wiring should use crimp contacts as shown below.

Wiring the trigger input

The trigger input is used to cause a BL/SR/RF Series device to begin reading.
The trigger input interval is on when 8.5 to 30 V DC is input.
The BL-U1 sensor power source can be used as the input power source.

Symbol

Explanation

Signal direction

TIM

Trigger input

Input
Input

+12 V OUT-

Sensor power source + side (+12 V DC, 300 mA)

Output

Sensor power source + side (0 V)

Output

COM

OK/NG output common

-

OK

OK output

Output

NG

NG output

Output

SDA

RS-422A data sending + side / RS-485 + side

Output/ input-

output

SDB

RS-422A data sending - side / RS-485 - side

Output/ input-

output

SG

Signal ground

-

RDA

RS-422A data reception + side

Input

RDB

RS-422A data reception - side

Input

TIM

Trigger input Sensor power source

(12 V DC, 300 mA)

OK/NG output

RS-422A/RS-485

+12V

OUT-

COM

OK

NG

SDA

SDB

SG

RDA

PDB

Round type

6.0 mm max.

Fork type

6.0 mm max.

+

+

Contact or
non-contact

8.5 to 30V DC

TIM

+12V

OUT–