Page 118: Compatible plcs -2, Plc link

background image

7-2

PLC

Link

7

7-1

PLC Link

A PLC link allows the N-410 to use the RS-232 interface to write directly to the internal memory
(data memory, data register) of a PLC (programmable controller).
No communications program is necessary for the N-410 to write directly to the PLC internal
memory, so fewer man-hours are spent on programming.

There are several limitations when using a PLC link instead of serial communications.
• RF-500/RF-550 devices cannot be connected to the N-410 when using a PLC link.
• The settings of an N-410 connected over a PLC link cannot be changed.
• Commands cannot be sent to BL Series or SR Series devices connected to the N-410.

However, read start and stop commands can be sent through the read control address.

• Commands cannot be sent to the N-410. In other words, functions such as starting auto-

polling, registering ID numbers cannot be performed through the PLC. Use the AutoID
Navigator to register ID numbers.

• Because communication takes a great deal of time, this is not geared towards high-

speed production lines.

Compatible PLCs

KEYENCE Corporation

Mitsubishi Electric

Omron

Important

Series

Connection method

Model

KV Series

Direct controller connection

KV-10/16/24/40
KV-P Series
KV-700/1000/3000

Multi-communication unit

KV-L20R
KV-L20V

Series

Connection method

Model

MELSEC Series

Computer link unit

AJ71UC24
A1SJ71UC24-R2/PRF

Serial communication unit

AJ71QC24N/-R2
A1SJ71QC24N/-R2
QJ71C24N/-R2

Series

Connection method

Model

SYSMAC Series

Internal CPU port

CJ1M-CPU11/12/13/21/22/23
CJIG-CPU42H/43H/44H/45H/65H/66H
CS1G-CPU42(H)/43(H)/44(H)/45(H)
CS1H-CPU63(H)/64(H)/65(H)/66(H)/67(H)

Communication port

CS1W-SCB21(-V1)/41(-V1)

Communication unit

CS1W-SCU21(-V1)
CJ1W-SCU21(-V1)/41(-V1)