The polling command in manual polling, Shifting in or out of the setting mode – KEYENCE N-410 User Manual
Page 108
6-12
S
6
6-4
Direct Control Command of the N-410 Series
The polling command in manual polling
Sends the polling command to a specified ID number in manual polling and obtains data from
the head that has the specified ID number.
Command sent
: %Pmm (mm = 01 to 31: ID number)
Response
: %Pmm - nnnn result data (nnnn = the number of characters in data)
* Results data includes read data and read error codes.
%Pmm - 0005e (e: No data)
Command sends procedure in manual polling
Sends the trigger input ON command (LON) to a BL Series device that has the ID number 3
and obtains the results data (KEYENCE) by sending the manual polling command.
Shifting in or out of the setting mode
Shift to the setting mode
Command sent : SSET
Response
: OK
Quit the setting mode
Command sent : SEND
Response
: OK
Operation
Command/Response
(1)
Send the trigger input on
%T03-LON
(2)
Respond to (1)
%T03-OK
(3)
Send the polling command
%P03
(4)-1
With results data
%P03-0011KEYENCE
(4)-2
Without results data
%P03-0005e
Reference
CR
CR
CR
CR
CR