beautypg.com

4 nx-50rs connections and wiring, Nx-50rs connections and wiring -16, Nx-50rs connections and wiring – KEYENCE N-410 User Manual

Page 38: Caution

background image

2-16

Inst
allatio

n

2

2-4

NX-50RS Connections and Wiring

The wiring for the NX-50RS is as follows.

Electrical wiring

Power terminal

If using a crimp contact, use a device of the following dimensions.

Electrical wiring

Connect a 24 V DC power source to the power terminal, as shown in the figure.

Use a class 2 output power source for 24 V power.

Use a D type ground pin (ground resistance no more than 100 ).

Terminal

Dimensions

Round terminal

a:8.0 mm Max

Y terminal

a:6.0mm Max

Item

Contents

Wire size

AWG14-20

Clamping torque

0.51 N

·

m (4.5 lbf

·

in)

Wire material

Copper

Wire type

Strand wire

Electrical
temperature rating

+60

°

C

Power supply

24 V DC ±10%

24 V DC 0 V

Twist

Protective
grounding

Caution