Lamp – Canon REALiS X600 User Manual
Page 54
User Command Specifications
9. Details of command LAMP
1
LAMP
LAMP
LAMP=
Lamp output setting parameters
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
Menu
[Image adjustments] - [Lamp mode]
[Image adjustments] - [Lamp mode]
-3
Setting
> LAMP=NORMAL
The lamp output is set to “NORMAL”.
< i:OK
Reference
> GET LAMP or ?LAMP
This retrieves the lamp output.
<
g:LAMP=SILENT
Acquisition of parameters which can be set
> RANGE LAMP
< r:LAMP=I, NORMAL, SILENT
"NORMAL" or "SILENT" can be set for the lamp output.
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
SX60
Silent cooling
NORMAL
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
This command is the same as the menu functions in the table below.
The current lamp output can be acquired using the applicable GET command.
Model
SX50
SX6
01.00**
Commands
Function
Parameter
Meaning
Format
Example
Lamp output setting
"i:OK" is returned if the parameter was set properly.
Parameter
Description
Response
X600
ID
Normal
SILENT
01.01**
01.01**
01.01**
SX50
○
○
SX6
SX60
X600
Model
Power
Input
Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
×
○
○
○
○
SX60
X600
○
Mode Control Setting Reference
For details, refer to the GET command.
Commands
supported
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
This command is used to set the light quantity of the lamp to "NORMAL" or "SILENT" (reduced light
quantity appropriate for silent cooling).
(Refer to the ZCONTDRV command and FCONTDRV command.)
○
○
PAGE 46