beautypg.com

Get noshowstate, Error list, Zcontdrv command and fcontdrv command – Canon REALiS X600 User Manual

Page 126

background image

User Command Specifications

9.Details of command GET NOSHOWSTATUS

1

GET NOSHOWSTATE

GET NOSHOWSTATE

GET□NOSHOWSTATE
?△NOSHOWSTATE

g:NOSHOWSTATE=

For all other responses, refer to

"Error List."

(1)

However, a "busy" response is given while the zoom or focus lens is being driven.

( Refer to the

ZCONTDRV command and FCONTDRV command.

(2) No show status ON/OFF is controlled using the "RC NOSHOW" command in the local mode. (Toggling)

> GET NOSHOWSTATE or ? NOSHOWSTATE
< g:NOSHOWSTATE=ON

*Commands are indicated by ">", and responses are indicated by "<".

When a command is not supported, "e:000A INVALID_PARAMETER" is returned.

Supported Command States

OFF

ON

PM

Ч

Ч

* If the command cannot be supported, "NOT_POWER_SUPPLIED" is returned as an error response.
*When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

X600

SX60

SX6

SX50

Remarks

D-RGB A-RGB1 A-RGB2

Comp

Video

S-Video D-Video SCART

None

Model Power supply

Input

Mode

Remote

Local

×

01.00**

01.01**

01.01**

01.01**

SX50

SX6

SX60

X600

Mode

OFF

Screen not temporarily off

ON

Screen temporarily off

Commands

Function

Format

NoShow status inquiry

Reference

Setting

Control

This inquiry can be made at any time provided that the power-on status is established.

This command is used to inquire about the current NoShow status.

Status

Meaning

ID

Commands

supported

Example

Description

Response

PAGE 118

This manual is related to the following products: