Mute – Canon REALiS X600 User Manual
Page 58
User Command Specifications
9. Details of command MUTE
1
MUTE
MUTE
MUTE=
Mute control parameter
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
-3
-4
-5
Setting
> MUTE=ON
This mutes the volume.
< i:OK
Reference
> GET MUTE or ?MUTE
This retrieves the volume state.
<
g:MUTE=ON
Acquisition of parameters which can be set
> RANGE MUTE
< r:MUTE=I, ON, OFF
"ON" or "OFF" can be set for muting control.
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
This returns the audio/beep sound to its original setting.
○
SX60
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
01.00**
01.01**
"i:OK" is returned if the parameter was set properly.
This turns off the audio/beep sound.
01.01**
01.01**
X600
Mute control enables simultaneous control of the audio and beep sound.
The current muting status can be acquired using the applicable GET command.
This command is used to set the sound output muting to ON or OFF.
SX50
SX6
Mode Control Setting Reference
Mute control
Parameter Meaning
ON
OFF
The mute setting is always "OFF" when the power has just been turned on.
This command is identical to pressing the MUTE button on the remote control.
ID
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
Commands
Function
Parameter
Description
Response
Format
Model
Power
Input
Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
×
○
○
○
○
SX60
X600
○
Commands
supported
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
For details, refer to the GET command.
○
○
○
Example