Vks/hks – Canon REALiS X600 User Manual
Page 56
User Command Specifications
9. Details of command VKS/HKS
1
VKS/HKS
VKS/HKS
VKS=
HKS=
Vertical/horizontal keystone distortion values
This sets the vertical and horizontal keystones.
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
-3
-4
-5
-6
Setting
> VKS=-23
This sets the vertical keystone to –23.
< i:OK
> HKS=10
This sets the horizontal keystone to 10.
< i:OK
Reference
> GET VKS or ?VKS
This retrieves the vertical keystone.
<
g:VKS=-23
> GET HKS or ?HKS
This retrieves the horizontal keystone.
< g:HKS=-23
Obtain settable parameter range (Min, Max)
> RANGE HKS
< r:HKS=N,-30,30
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* If the necessary signals are not input, 'NO_SIGNAL' is returned.
* "i:BUSY" may be returned if the power status is being switched.
01.00**
The GET command can be used to obtain the current vertical/horizontal keystone value.
X600
○
○
Setting Reference
SX60
Description
Response "i:OK" is returned if the parameter was set properly.
This command is identical to pressing the “KEYSTONE” button on the remote control or front pa
Example
SX50
SX6
Commands
Changing the vertical keystone value modifies the setting range of the horizontal keystone
value, and changing the horizontal keystone value modifies the setting range of the vertical
Function
Parameter
Number
Vertical/Horizontal keystone setting
Commands
supported
Mode Control
01.01**
01.01**
01.01**
○
○
Model
Power
Input
Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
Ч
○
Ч
SX6
○
○
○
○
○
○
○
○
○
○
×
SX60
X600
Format
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
The RANGE command can be used to obtain the parameter range that can be set at
that time.
The settable keystone range varies depending on the input signal, screen size, number of
horizontal and vertical dots, and other factors.
Use the “RANGE” command to obtain the range of settable values immediately before setting
the vertical value and horizontal value.
For details, refer to the GET command.
Any value from -30 to 30 can be set for the horizontal
keystone distortion.
PAGE 48