User Command Specifications
9. Details of command CONT
1
CONT
CONT
CONT=
Contrast setting (-20 to 20)
This sets the screen contrast.
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
Menu
[Image adjustments] - [Contrast]
[Image adjustments] - [Contrast]
-3
-4
Setting
> CONT=3
This sets the contrast to +3.
< i:OK
Reference
> GET CONT or ?CONT
This retrieves the contrast.
< g:CONT=3
Obtain settable parameter range (Min, Max)
> RANGE CONT
< r:CONT=N, -20, 20
Any value from -20 to 20 can be set for the contrast.
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Contrast setting
"i:OK" is returned if the parameter was set properly.
SX50
SX6
SX60
X600
01.01**
Commands
Function
Parameter
Description
Response
Format
Number
Model
SX50
SX6
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
The RANGE command can be used to obtain the parameter range that can be set at
that time.
○
○
○
This command is the same as the menu functions in the table below.
The currently selected input signal and image mode are used for these settings.
The current contrast can be acquired using the applicable GET command.
SX60
X600
01.00**
01.01**
01.01**
Model
Power
Input
Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
×
○
○
○
○
SX60
X600
○
Mode Control Setting Reference
Commands
supported
For details, refer to the RANGE command.
For all other responses, refer to "Error List."
(Refer to the ZCONTDRV command and FCONTDRV command.)
For details, refer to the GET command.
Example
○