User Command Specifications
9. Details of command GAMMA
1
GAMMA
GAMMA
GAMMA=
Gamma adjustment (-4 to 4)
This performs the Gamma adjustment.
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
Menu
[Image adjustments] - [Gamma]
[Image adjustments] - [Gamma]
-3
-4
Setting
> GAMMA=-1
This sets the gamma correction to –1.
< i:OK
Reference
> GET GAMMA or ?GAMMA
This retrieves the gamma correction.
< g:GAMMA=3
Obtain settable parameter range (Min, Max)
> RANGE GAMMA
< r:GAMMA=N, -4, 4
Any value from -4 to 4 can be set for the gamma.
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
01.01**
The current gamma adjustment can be acquired using the applicable GET command.
SX60
01.00**
Control
SX50
SX6
SX60
X600
○
○
SX50
SX6
Commands
Function
Parameter
Description
Response
Format
The RANGE command can be used to obtain the parameter range that can be set at
that time.
Mode
Number
Model
For all other responses, refer to "Error List."
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
Model
Power
Input
Mode
Remote Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
×
○
○
○
○
SX60
X600
○
Example
Commands
supported
○
○
01.01**
01.01**
Setting Reference
For details, refer to the GET command.
X600
This sets the currently selected input signal and image mode.
Gamma adjustment
"i:OK" is returned if the parameter was set properly.
This command is the same as the menu functions in the table below.
For details, refer to the RANGE command.
(Refer to the ZCONTDRV command and FCONTDRV command.)