Get noshow – Canon REALiS X600 User Manual
Page 117
User Command Specifications
9.Details of command GET NOSHOW
1
GET NOSHOW
GET NOSHOW
GET□NOSHOW
?△NOSHOW
g:NOSHOW=
For all other responses, refer to "Error List."
-1
A "busy" response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
-2 The current display screen when nothing is shown can be set by the NOSHOW command.
> GET NOSHOW or ? NOSHOW
< g:NOSHOW=LOGO
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command States
OFF ON
PM
Ч
○
Ч
Ч
○
Ч
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
This inquiry can be made when the projector is in both the remote mode and power-on status at
the same time.
User screen
Reference
Mode Control Setting
Blue screen
LOGO
Commands
Setting
Meaning
BLACK
Black screen
01.01**
01.01**
Description
Function
Format
Display screen when nothing is shown setting inquiry
Response
This inquires about the current setting for the screen to be displayed when nothing is shown.
ID
BLUE
SX50
SX6
SX60
X600
01.01**
○
○
○
○
01.00**
Model
Power
Input
Mode
Remote
Local
Remarks
D-RGB A-RGB1 A-RGB2 Comp
Video
S-Video D-Video SCART
None
SX50
○
○
○
○
○
○
–
–
○
○
×
SX6
○
○
○
○
○
○
○
○
○
○
×
SX60
Example
X600
Commands
supported