Canon REALiS X600 User Manual
Page 14
User Command Specifications
5. Control Mode
1 5. Control Mode
The table below shows the states and limitations of the LOCAL and REMOTE control modes.
Mode
Item
Status
State indicator
Constant remote indicator ※2
ALM
ALM state indicator
ALM state indicator
・
AC power supply to projector
・
REMOTE command
・
Manual power on/off
・
LOCAL command
・
Power management standby/exit mode transfer
Main unit keys All available
Only POWER button is available
Emulation
Available
※
1
Not available
5 minutes elapsed from no signal
Operation is as follows depending on the model.
・
・
・
・
Signal input
・
REMOTE command
・
Remote control button pressed
・
Main unit button pressed
・
Emulation
For the SX50
All commands except for "RC" and "MAIN"
REMOTE
LOCAL
GET
MODE
MAIN
RC
For the SX6, SX60 or X600
GET
COMVER
GET
ERROR
GET
FREEZE
GET
INPUT
GET
LAMPCOUNTER
GET
MODE
GET
MUTE
GET
NOSHOWSTATUS
GET
POWER
GET
PRODCODE
GET
ROMVER
GET
SIGNALSTATUS
LOCAL
MAIN
RC
REMOTE
Special mode
Executable with remote control or main unit buttons Not executable in any state
(Service mode)
*1 However, switching to the USB mouse function or Special mode is not allowed.
*2 If the control mode is REMOTE, the following are displayed regardless of whether the power is on or off.
*3 When the power management setting is "standby" or "exit"
LED indicator pattern during REMOTE mode
■
■
Mode where projector control/operation is
performed by a PC or other external device.
(The PC or other external device is connected by
a serial cable.)
Mode where projector control/operation is
performed by the main unit or remote control.
Initial mode when microcomputer is started.
5. Control Mode
LOCAL mode
Description
REMOTE mode
Remote control
keys
All available
Command/parameter
Remarks
Commands supported
Command/parameter
Remarks
5 minutes elapsed from no
signal
Model
Return
No switching to standby or exit
mode.
Transition method
Operation
Operation
buttons
LED
Switching
Power
management
standby and exit
modes
※
3
Control is switched to "local
mode" after mode switching.
SX6
SX60
X600
SX50
Only POWER button is available
PAGE 9