Canon REALiS X600 User Manual
Page 11
User Command Specifications
3. Communication Flow
1 3. Communication Flow
One response is always returned for each command sent from the PC.
Within Tr
*The timeout interval between command and response (Tr) is 10 seconds.
Response
reception
timeout
If a response is not received within Tr (timeout interval between command and response) while in response reception
standby after sending a command at the PC, resend the command in the “response reception timeout”.
Response
PC
Commands
Projector
3. Communication Flow
Transmission
sent
Transmission
received
Command/
Response
At the sending side (PC), the transmission is sent within character intervals of Tc (character interval timeout).
At the receiving side (Projector), data able to be received within the character interval of Tc is held, and receiving of a
delimiter is considered “transmission received”.
If a received character interval exceeds Tc or a delimiter is not received within 256 characters, all data already received is
lost, and the mode is reset to receive standby again.
(However, note that a response may not be returned when the internal receive buffer overflows due to reception of a large
amount of data.)
PAGE 6