beautypg.com

Reset – Canon REALiS X600 User Manual

Page 55

background image

User Command Specifications

9. Details of command RESET

1

RESET

RESET

RESET:ID>

Reset parameters

This resets the projector settings.

-1

A "busy" response is given while the zoom or focus lens is being driven.

-2 What can be specified by the reset parameters for each "reset type" is provided below.

Reset of lamp on time

(a) The counter indicating the lamp replacement period is reset.
(b)

(c) Execute this command after replacing the lamp.

Current image adjustment reset

(a) The adjustment settings of the currently-selected image mode are initialized.
(b) This command is identical to the Reset function in the Image adj. menu.

Reset of system settings

(a) The following items are initialized.

- Image adjustment items (all image modes)
- Initial settings executed
* For details, refer to 'RESET items' at the end of these specifications.

(b)

Factory settings

(a) The following items are initialized.

- Image adjustment items (all image modes)
- Initial settings executed
- Input source <-A-RGB2
- Language <- English
* For details, refer to 'RESET items' at the end of these specifications.

-3 Notes

(a)
(b)

(c)

Control

> RESET LAMPTIME

This resets the lamp on time.

< i:OK

* Commands are indicated by ">", and responses are indicated by "<".

Supported Command States

OFF ON

PM

Ч

Ч

Ч

Ч

* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.

This command works in the same way as the menu [System settings] - [Initial settings]
function.

01.01**

01.01**

01.01**

'NO_SIGNAL' may be returned as the response to the command after 'Current image
adjustment reset' or 'System initial setting' has been executed.

SX50

SX6

SX60

X600

Mode

Current image adjustment reset

LAMPTIME Lamp on time reset

An ‘i:OK’ is returned when the reset process is successful.
Furthermore, the internal status established when a response other than the normal response
("i:OK") has been returned is indeterminate.
For all other responses, refer to "Error List."

Control Setting Reference

Commands

Function

Parameter

Format

Meaning

Parameter

Reset

ID

IMAGE

SYSTEM Initial system settings

(Refer to the ZCONTDRV command and FCONTDRV command.)

If there is an input signal, the image adjustment items are initialized and then the
adjustment values are optimized for the signal.

It can be executed when the projector is in both the remote mode and power-on status at the
same time.

This command is identical to the Reset function under Lamp counter in the System
settings menu.

Description

Response

Factory settings

ALL

Model

Power

Input

D-RGB A-RGB1 A-RGB2 Comp

Video

D-Video SCART

S-Video

None

Remarks

Mode

Remote Local

×

SX6

×

SX50

SX60

X600

Commands

supported

Example

The power must never be turned off while this command is being executed!

01.00**

After the 'Factory settings,' be absolutely sure to turn the power off and then restart.

PAGE 47