3 single drives with 120 %overload, Single drives with 120 % overload, Technical data – Lenze 8200 Frequency inverters User Manual
Page 55: 3 single drives with 120 % overload

Technical Data
8200SHB0199
3-23
3.6.3
Single drives with 120 % overload
The table values are valid for operation of 82XX controllers with matching motor
and 120 % overload in pump and fan drives.
Type
Mains input L1, L2, L3, PE / motor connection U, V, W, PE
Type
Operation with mains filter/mains choke
Fuse F1, F2, F3
E.l.c.b.
Cable cross-section
1)
VDE
UL
VDE
mm
2
AWG
8211
M 6A
-
B 6A
1
17
8212
M 6A
-
B 6A
1
17
8213
M 10A
-
B 10A
1.5
15
8214
M 10A
-
B 10A
1.5
15
8215
M 20A
-
B 20A
4
11
8216
M 20A
-
B 20A
4
11
8217
M 32A
-
B 32A
6
10
8218
M 32A
-
B 32A
6
10
Type
Mains input L1, L2, L3, PE / motor connection U, V, W, PE
Type
Operation only with mains filter/mains choke
Fuse F1, F2, F3
E.l.c.b.
Cable cross-section
1)
VDE
UL
VDE
mm
2
AWG
8221
M 50A
50A
--
16
5
8222
M 63A
63A
--
25
3
8223
M 80A
80A
--
25
3
8224
M 125A
125A
--
70
2 / 0
8225
M 160A
175A
--
95
3 / 0
8226
M 160A
175A
--
95
3 / 0
8227
M 200A
200A
--
120
4 / 0
8241
M 6A
5A
B 6A
1
17
8242
M 6A
5A
B 6A
1
17
8243
M 10A
10A
B 10A
1.5
15
8244
M 10A
10A
B 10A
1.5
15
8245
M 20A
20A
B 20A
4
11
8246
M 32A
25A
B 32A
6
10
1)
Observe national and regional regulations (e.g. VDE/EVU)!
Show/Hide Bookmarks