Configuration
8200SHB0199
7-86
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Choice
Lenze
Name
C003
¤ Save parameter set
-1-
-0-
Data will not be saved on EEPROM;
all data will be lost when switching
off the mains
-1-
Data will be saved on EEPROM;
setting when switching on the
mains
Page 7-8
-0- only valid for
C010, C011, C012,
C013, C037, C038,
C105, C181 and
C182
C004
¤ Switch-on display
-0-
-0-
Field frequency f
d
-1-
Unit load
-2-
Motor current
Page 7-62
C005
¤ Configuration
-0-
-0-
Operation with open-loop control
via terminal 8
-1-
Operation with open-loop control
via terminal 8 with setpoint
summation via frequency input E1
-2-
Operation with open-loop control
via frequency input E1 with setpoint
summation via terminal 8
Page 7-26,
7-61
If C005 = -0-
-
2 ms cycle time
If C005 = -1- ... -7-
-
4 ms cycle time
C005 = -4-, -5- not
applicable
-3-
Open loop operation via frequency
input E1 with limitation of the
apparent motor current via
terminal 8
C005 = -3-
with
C014 = -2-, -4-
possible
-6-
Operation with closed-loop control;
setpoint via terminal 8 with digital
frequency feedback via terminal E1
-7-
Operation with closed-loop control,
setpoint via frequency input E1 with
analog feedback via terminal 8
C007
¤ Terminal
configuration
-0-
E4
E3
E2
E1
-0-
CW/CCW GSB
JOG1/2/3
-1-
CW/CCW PAR
JOG1/2/3
-2-
CW/CCW QSP
JOG1/2/3
-3-
CW/CCW PAR
GSB
JOG1
-4-
CW/CCW QSP
PAR
JOG1
-5-
CW/CCW GSB
TRIP set
JOG1
-6-
CW/CCW PAR
TRIP set
JOG1
-7-
CW/CCW PAR
GSB
TRIP set
-8-
CW/CCW QSP
PAR
TRIP set
-9-
CW/CCW QSP
TRIP set
JOG1
-10-
CW/CCWTRIP set
UP
DOWN
Page 7-10,
7-44, 7-46,
7-50, 7-54,
7-58,
-
R =
CW rotation
-
L =
CCW rotation
-
GSB =
DC-injection brake
-
PAR =
Parameter set
changeover
-
JOG =
Fixed frequency
-
QSP =
Quick stop