7.5.10.3 Frequency precontrol
Code
Name
Possible settings
IMPORTANT
Code
Name
Lenze
Choice
Info
IMPORTANT
C238
¤ Frequency
precontrol
-1-
-0-
No precontrol
-1-
With setpoint precontrol
Function
C238 = -1-
-
The process controller has only limited influence on the process.
The following setpoint precontrol is possible:
A The setpoint of the process controller is derived from the precontrol value (C181 = 0).
- Applications with frequency precontrol are e.g. speed controls.
B The setpoint of the process controller is selected under C181 (C181
0).
- Applications are e.g. dancer controls, pressure and flow-rate controls
7.5.10.4 Frequency setting range
Code
Name
Possible settings
IMPORTANT
Code
Name
Lenze
Choice
Info
IMPORTANT
C239
¤ Frequency setting
range
-0-
-0-
Bipolar
-1-
Unipolar
Function
C239 = -0-
-
Allows both directions of rotations for the control process.
C239 = -1-
-
Allows only one direction of rotation for the control process.
Application with frequency setting range are, for instance:
-
Fan controls
-
Dancer controls
Important
Only if C005 > -0-, C239 has an influence.