4 types 8221 to 8224, Types 8221 to 8224, Technical data – Lenze 8200 Frequency inverters User Manual
Page 42

Technical Data
8200SHB0199
3-10
3.4.4
Types 8221 to 8224
150 % overload
Type
8221
8222
8223
8224
Order No.
EVF8221-E
EVF8222-E
EVF8223-E
EVF8224-E
Variant ”Cold Plate”
Type
8221-V003
8222-V003
Order No.
EVF8221-C-V003 EVF8222-C-V003
Variant “HVAC”
Type
8221-V020
8222-V020
8223-V020
8224-V020
Order No.
EVF8221-E-V020 EVF8222-E-V020 EVF8223-E-V020 EVF8224-E-V020
Mains voltage
V
r
[V]
320 V -0 %
$ V
r
$ 528 V +0 %; 45 Hz ¡ 65 Hz á0 %
Alternative DC supply
V
DC
[V]
460 V -0 %
$ V
DC
$ 740 V +0 %
Mains current
with mains filter/mains choke
without mains filter/mains choke
I
mains
[A]
I
mains
[A]
29.0
43.5
42.0
--
55.0
--
80.0
--
Data for mains operation with 3 AC / 400 V / 50 Hz/60 Hz ; 460 V
$ V
DC
$ 620 V or
3 AC / 480 V / 50 Hz/60 Hz; 460 V
$ V
DC
$ 740 V
400 V
480 V
400 V
480 V
400 V
480 V
400 V
480 V
Motor power (4 pole ASM)
at 4 kHz/8 kHz*
P
r
[kW]
15
18.5
22
30
30
37
45
55
Motor power (4 pole ASM)
at 4 kHz/8 kHz*
P
r
[hp]
20
25
30
40
40
49.5
60
74
Output power U, V, W at 4 kHz/8 kHz*
S
r8
[kVA]
22.2
26.6
32.6
39.1
41.6
49.9
61.7
73.9
Output power + U
G
, -U
G
1)
P
DC
[kW]
10.2
11.8
4.0
4.6
0
0
5.1
5.9
Output
current
4 kHz*
I
r4
[A]
32
32
47
47
59
56
89
84
Output
current
8 kHz*
I
r8
[A]
32
32
47
47
59
56
89
84
12 kHz*
I
r12
[A]
27
25
40
37
50
47
71
67
16 kHz*
I
r16
[A]
24
22
35
33
44
41
62
58
Noise optimised 4 kHz*
4)
I
r4
[A]
32
30.5
47
45
59
56
89
84
Noise optimised 8 kHz*
4)
I
r8
[A]
29
27
43
41
47
5)
44
5)
59
5)
55
5)
Noise optimised 12 kHz*
I
r12
[A]
25
24
37
35
44
38
62
58
Noise optimised 16 kHz*
I
r16
[A]
21
19
30
28
35
30
53
49
Max.
output
4 kHz*
I
rmax4
[A]
48
48
70.5
70.5
89
84
134
126
Max.
output
current
8 kHz*
I
rmax8
[A]
48
48
70.5
70.5
89
84
134
126
current
for 60 s
2)
12 kHz*
I
rmax12
[A]
40
38
59
56
75
70
92
87
for 60 s
2)
16 kHz*
I
rmax16
[A]
36
33
53
49
66
61
81
75
Noise optimised 4 kHz*
4)
I
rmax4
[A]
48
46
70.5
66.5
89
56
134
126
Noise optimised 8 kHz*
4)
I
rmax8
[A]
43
41
64
61
70
5)
65
5)
88
5)
82
5)
Noise optimised 12 kHz*
I
rmax12
[A]
38
36
56
53
66
57
81
75
Noise optimised 16 kHz*
I
rmax16
[A]
31
29
46
42
53
45
69
63
Motor voltage
3)
V
M
[V]
0 - 3 x V
mains
/ 0 Hz
¡ 50 Hz, if required up to 480 Hz
Power loss (operation with I
rx
)
P
loss
[W]
430
640
810
1100
Show/Hide Bookmarks