3 oscillation damping, Oscillation damping, Configuration – Lenze 8200 Frequency inverters User Manual
Page 168

Configuration
8200SHB0199
7-31
7.5.9.3
Oscillation damping
Setting range 820X/821X:
Function not available.
Setting range 822X/824X:
Code
Name
Possible settings
IMPORTANT
Lenze
Choice
Info
C079 Oscillation damping
Is not transferred when
transferring
parameters via the
822X/824X
5
0
{1}
80
transferring
parameters via the
operating module.
Function
Suppression of idling oscillations when:
-
a drive does not match, i.e. rated controller power - motor
e.g. operation with high chopper frequency and the related power derating,
-
operation of higher-pole motors,
-
operation of special motors,
-
having a resonance phenomenon in the drive set.
Adjustment
1.Approach the area with speed oscillations.
2.Reduce the oscillation by changing C079 step by step.
- Indicators for smooth running can be a uniform motor current or the reduction of the
mechanical vibrations in the bearing seat.
Important
-
Parameter transfer from C079 not possible via keypad.
-
Compensate the resonances in speed controlled operation via the parameters of the controller.